MOULD YOUR FUTURE - MILACRON WAY                                                          TECHNOLOGY FOR GLOBAL MARKET















TOGGLE INJECTION MOULDING MACHINES


TECHNICAL FEATURES
 



     CLAMP

 

  • Adjustable individual Pressure Setting of each stage

  • Position based acceleration / deceleration for accurate position Switching and control of speeds and pressures

  • Programmable Clamp position with its feedback by linear transducer

  • Programmable Ejector Stroke, Pressure and Speed

  • Proportional Speed Control with 5 closing and opening speed

  • Quick auto Clamp forces setting

  • Safety Guard suitable for Robot / Sprue picker

  • Sensitive Mould Protection with try again circuit

  • Stage wise Actual Time Display

  • Insert Moulding


 
     INJECTION
  • Injection Velocity and Pressure Steps (6 Speed and 15 Pressure  profile)

  • Adjustable Profile to switch over from fill to pack based on Position,Time and Cavity pressure

  • Aluminium Chequered Plate provided below Purge area

  • Availability of auto heat startup and shutdown with timer based sprue break facility

  • Choice extended for Injection decompression before / after refilling or both

  • Extruder rpm adjustment on screen and actual rpm display

  • Eyebolt provision for Barrel lifting

  • Linear position Transducer assistance for real time read out and accurate Control

  • Nozzle Contact activation force by Limit switch

  • PID Control Algorithms for barrel heating zone

  • Sprue break feature with timer

  • User Friendly design for Cold slug removal, Semi auto purge, Intrusion moulding


     EJECTOR
  • Sequential Ejector, speed adjustable through screen

  • Ejector Stay Forward

  • Intermediate Retract set point

  • Linear Transducer provided for ejector position read out

  • Pulsating Ejector Strokes with ejector forward / retractd well      timer

  • Two-stage Ejector forward profile with soft eject


    TEMPERATURE CONTROL
  • Accurate PID Temperature Controls settable through operator panel for nozzle and barrel zones

  • Actual Current Display of individual heating zone with heater failure detection

  • Feed Throat Temperature Indication

  • Heat standby after set number of cycles

  • High/Low Temperature Alarm Bands

  • Set and Actual Temperature data with bar graph

  • Soak timer for Cold start protection

 

     HYDRAULICS
  • Hydraulic Controlled Variable Volume Pump

  • Continuous oil filtration with 10 micron filter and audiable alarm for filter clogging

  • Ergonormic hydraulic layout for easy approach

  • Pre- heating circuit for hydraulic oil

  • Low oil level monitoring

 
 
 
 
 
 
 
Quick Tour     |     Ask the Expert     Any Comments?
Contact Webmaster

    © Ferromatik Milacron India Ltd., Ahmedabad.